Fluke MET/CAL Procedure ============================================================================= INSTRUMENT: Philips PM 2518: CAL ADJ /5500 INSTRUMENT: Philips PM 2618: CAL ADJ /5500 INSTRUMENT: Philips PM 2718: CAL ADJ /5500 DATE: 08-Sep-97 AUTHOR: Fluke Corporation REVISION: $Revision: 1.4 $ ADJUSTMENT THRESHOLD: 70% NUMBER OF TESTS: 1 NUMBER OF LINES: 199 CONFIGURATION: Fluke 5500A ============================================================================= # # Compatibility: # 5500/CAL 4.0 or MET/CAL 4.0 or later. # # Subprocedures: # None # # Required Files: # pm2618v.bmp # pm2618lc.bmp # pm2618hc.bmp # # System Specifications: # TUR calculation is based on specification interval of the accuracy file. # The default 5500A accuracy file contains 90 day specs. # # Fluke makes no warranty, expressed or implied, as to the fitness # or suitability of this procedure in the customer's application. # STEP FSC RANGE NOMINAL TOLERANCE MOD1 MOD2 3 4 CON 1.001 ASK- P F V 1.002 ASK+ K X 1.003 HEAD PRELIMINARY INSTRUCTIONS 1.004 DISP Warm-up time: NONE 1.004 DISP Temperature: 18 - 28 degC 1.004 DISP Humidity: <80% 1.005 DISP [32] WARNING 1.005 DISP HIGH VOLTAGE is used or exposed during the performance 1.005 DISP of this calibration. DEATH ON CONTACT may result if 1.005 DISP personnel fail to observe safety precautions. 1.006 DISP This procedure performs the ELECTRONIC FINE ADJUSTMENT 1.006 DISP of the multimeter. If components have been replaced, 1.006 DISP the MANUAL COARSE & FINE adjustments may have to be 1.006 DISP performed. - SEE SERVICE MANUAL - 1.007 HEAD CALIBRATION MODE SETUP 1.008 DISP Set the POWER switch to OFF. 1.008 DISP 1.008 DISP Remove the Battery Compartment cover. 1.009 JMPT 1.011 PHILIPS PM 2518: CAL ADJ /5500 1.010 JMP 1.013 1.011 DISP Set the FUNCTION switch to AC VOLTS. 1.012 JMP 1.014 1.013 DISP Set the FUNCTION switch to Hz. 1.014 DISP With a screwdriver, shortcircuit the two pins that are 1.014 DISP situated in the round hole (marked with "A") in the 1.014 DISP battery compartment. 1.014 DISP 1.014 DISP Set the POWER switch to ON (while shorting pins). 1.015 DISP *NOTE* Check the last digit in the LCD display for a 1.015 DISP "c" indicating CAL mode selected. 1.016 HEAD DC VOLTAGE 1.017 PIC pm2618v 1.018 DISP Set the FUNCTION switch to DC VOLTS. 1.019 5500 1000.0mV S 2W 1.020 DISP Press the RNG button to select the 1000mV Range. 1.021 DISP Press the button to calibrate this range. 1.022 DISP Press the RNG button to select the 10.00V Range. 1.023 5500 10.000V S 2W 1.024 DISP Press the button to calibrate this range. 1.025 DISP Press the RNG button to select the 100.0V Range. 1.026 5500 100.00V S 2W 1.027 DISP Press the button to calibrate this range. 1.028 JMPF 1.064 PHILIPS PM2718: CAL ADJ /5500 1.029 MESS 1.030 DISP Due to the high accuracy of the DC VOLTAGE function of 1.030 DISP the PM2718, the fine adjustment of the DC voltage must 1.030 DISP be made +/- 1 digit on the display. In the "CAL" mode 1.030 DISP you lose the last digit of resolution, so to complete 1.030 DISP the calibration properly you must EXIT cal mode read the 1.030 DISP "normal" indication, and if necessary repeat the CAL 1.030 DISP with value obtained in normal mode. 1.031 DISP Set the POWER switch to OFF. 1.031 DISP 1.031 DISP Set the POWER switch to ON (DO NOT SHORT THE TEST PINS)! 1.032 DISP Set the FUNCTION switch to DC VOLTS. 1.033 5500 1000.0mV S 2W 1.034 MEMI Enter UUT reading in millivolts. 1.035 MATH M[1] = MEM 1.036 5500 10.000V S 2W 1.037 MEMI Enter UUT reading in volts. 1.038 MATH M[2] = MEM 1.039 5500 100.00V S 2W 1.040 MEMI Enter UUT reading in volts. 1.041 MATH M[3] = MEM 1.042 DISP Set the POWER switch to OFF. 1.042 DISP 1.042 DISP Set the FUNCTION switch to Hz. 1.043 DISP With a screwdriver, shortcircuit the two pins that are 1.043 DISP situated in the round hole (marked with "A") in the 1.043 DISP battery compartment. 1.043 DISP 1.043 DISP Set the POWER switch to ON (while shorting pins). 1.044 DISP *NOTE* Check the last digit in the LCD display for a 1.044 DISP "c" indicating CAL mode selected. 1.045 DISP Set the FUNCTION switch to DC VOLTS. 1.046 MATH MEM1 = M[1] - 1000 1.047 JMPZ 1.052 0.1U 1.048 MATH MEM = M[1] 1.049 DISP Press the RNG button to select the 1000mV Range. 1.050 5500 mV S 2W 1.051 DISP Press the button to calibrate this range. 1.052 MATH MEM1 = M[2] - 10 1.053 JMPZ 1.058 0.001U 1.054 MATH MEM = M[2] 1.055 DISP Press the RNG button to select the 10.00V Range. 1.056 5500 V S 2W 1.057 DISP Press the button to calibrate this range. 1.058 MATH MEM1 = M[3] - 100 1.059 JMPZ 1.064 0.01U 1.060 MATH MEM = M[3] 1.061 DISP Press the RNG button to select the 100.0V Range. 1.062 5500 V S 2W 1.063 DISP Press the button to calibrate this range. 1.064 HEAD AC VOLTAGE 1.065 DISP Set the FUNCTION switch to AC VOLTS. 1.066 DISP Press the RNG button to select the 10.00V Range. 1.067 5500 10.000V 60H SI S 2W 1.068 DISP Press the button to calibrate this range. 1.069 DISP Press the RNG button to select the 100.0V Range. 1.070 5500 100.00V 60H SI S 2W 1.071 DISP Press the button to calibrate this range. 1.072 JMPT 1.081 PHILIPS PM 2518: CAL ADJ /5500 1.073 HEAD FREQUENCY 1.074 DISP Set the FUNCTION switch to FREQUENCY (Hz). 1.075 DISP Press the RNG button to select the 10.00kHz Range. 1.076 5500 10.000kH 1V SQ S 2W 1.077 DISP Press the button to calibrate this range. 1.078 DISP Press the RNG button to select the 100.0kHz Range. 1.079 5500 100.00kH 1V SQ S 2W 1.080 DISP Press the button to calibrate this range. 1.081 HEAD RESISTANCE 1.082 DISP Connect the 5500A to the UUT as follows: 1.082 DISP [32] 5500A AUX HI to UUT V/OHM 1.082 DISP [32] 5500A AUX LO to UUT COM 1.082 DISP [32] 5500A NORMAL HI to UUT V/OHM 1.082 DISP [32] 5500A NORMAL LO to UUT COM 1.082 DISP Connect the SENSE leads DIRECTLY to the UUT. Connect 1.082 DISP the NORMAL leads to the SENSE leads AT the UUT. 1.083 DISP Set the FUNCTION switch to OHMS. 1.084 DISP Press the RNG button to select the 1000 Ohm Range. 1.085 5500 1.0000kZ S CW 1.086 DISP Press the button to calibrate this range. 1.087 DISP Press the RNG button to select the 10.00 KOhm Range. 1.088 5500 10.000kZ S CW 1.089 DISP Press the button to calibrate this range. 1.090 DISP Press the RNG button to select the 100.0 KOhm Range. 1.091 5500 100.00kZ S CW 1.092 DISP Press the button to calibrate this range. 1.093 DISP Press the RNG button to select the 1000 KOhm Range. 1.094 5500 1.0000MZ S 2W 1.095 DISP Press the button to calibrate this range. 1.096 DISP Press the RNG button to select the 10.00 MOhm Range. 1.097 5500 10.000MZ S 2W 1.098 DISP Press the button to calibrate this range. 1.099 HEAD TEMPERATURE 1.100 OPBR The temperature calibration requires a connection to the 1.100 OPBR PROBE INPUT connector pins. 1.100 OPBR 1.100 OPBR Do you wist to perform the TEMPERATURE CALIBRATION? 1.101 JMPF 1.108 1.102 PIC pm2618tc 1.103 ASK- U # Insure that lead resistance is less than 10 Ohms. 1.104 5500 100.00Z S 2W 1.105 ASK+ U 1.106 DISP Press the button to calibrate this range. 1.107 JMP 1.108 1.108 HEAD DC CURRENT 1.109 DISP Set the FUNCTION switch to DC CURRENT. 1.110 PIC pm2618lc 1.111 DISP Press the RNG button to select the 20.0mA Range. 1.112 5500 20.000mA S 2W 1.113 DISP Press the button to calibrate this range. 1.114 PIC pm2618hc 1.115 DISP Press the RNG button to select the 2.00A Range. 1.116 5500 2.0000A S 2W 1.117 DISP Press the button to calibrate this range. 1.118 HEAD AC CURRENT 1.119 DISP Set the FUNCTION switch to AC CURRENT. 1.120 PIC pm2618lc 1.121 DISP Press the RNG button to select the 20.0mA Range. 1.122 5500 20.000mA 60H SI S 2W 1.123 DISP Press the button to calibrate this range. 1.124 5500 * S 1.125 DISP Turn OFF the UUT. 1.126 END